PowerFlex 700L Technical Data
Publication 20L-TD001A 5
Communication Modules
DPI communication modules provide fast and efficient control and/or data exchange over the following interfaces:
• DeviceNet
™
• ControlNet
™
• EtherNet/IP
™
• Remote I/O
™
• Serial Communications
• Other open control and communication networks
Unsurpassed Capability in Network Communications
PowerFlex drives are fully compatible with the wide variety of Allen-Bradley DPI
™
communication adapters, offering the
following benefits:
PowerFlex Architecture-Class LCD Human Interface Modules
• An LCD Human Interface Module (also used with the PowerFlex 70, PowerFlex 700, PowerFlex 700S, and PowerFlex
700H) provides multilingual text for startup, metering, programming, and troubleshooting.
• Large and easy to read 7 line x 21 character backlit display
• Alternate function keys for shortcuts to common tasks
• “Calculator-like” number pad for fast and easy data entry (Full Numeric version only)
• Control keys for local start, stop, speed, and direction
• Remote versions for panel mount applications
PC-based Configuration Tools
• DriveExplorer
™
and DriveExplorer Lite. Simple and flexible “On-line” tools for monitoring and configuring while
connected to a drive.
• DriveTools
™
SP. A suite of software tools which provide an intuitive means for programming, troubleshooting, and
maintaining Allen-Bradley AC and DC drives.
BACnet
®
DeviceNet
™
ControlNet
™
EtherNet/IP
™
Remote I/O
RS485 DF1
PROFIBUS DP
Interbus
™
LonWorks
™
Modbus RTU
Modbus TCP
Metasys N2
Siemens P1 FLN
Bluetooth
®
Description
✔✔✔ Unconnected Messaging permits other network devices (e.g. PanelView
™
) to communicate directly to a drive without routing the
communication through the network scanner.
✔✔✔✔ ✔ ✔ ✔Adapter Routing – Plug PC into one drive and talk to all other Allen-Bradley drives on same network, without being routed through
the network scanner.
✔✔✔✔✔✔✔✔✔✔✔✔✔✔Access to 100% of all parameters over the network.
✔✔ ✔ ✔ AutoBaud capability makes initial connections less problematic.
✔ Change of State significantly reduces network traffic by configuring control messages to be sent only upon customer defined states.
Very flexible configuration for each node (Example: “reference must change by more than 5%”).
✔✔ Peer Control provides master-slave type control between drives, where one or more slave drives (consumers) can run based on the
status of a master drive (producer), which can also significantly reduce network traffic.
✔ Automatic Device Replacement (ADR) saves significant time and effort when replacing a drive, by allowing the scanner to be
configured to automatically detect a new drive and download the required parameter settings.
✔✔✔✔✔✔✔✔✔✔✔✔✔✔Flexible Fault Configuration – Adapters can be programmed to take fault based actions such as ramp to stop, coast-to-stop, and
hold last state, as well as send user configurable logic control and speed reference values. In addition, different actions can be taken
based on whether the network experienced a serious problem (broken cable, etc.) versus a network idle condition (PLC set to
“Program”).