Dimplex KSS 2504 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Split-System-Klimaanlagen Dimplex KSS 2504 herunter. Dimplex KSS 2504 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
KSS 2504
KSS 3204
KSS 4504
KSS 6004
Split Air Conditioner for Wall Mounting
Installation and Operating Instructions 453322.66.11 06/07/B
Contents: Page
Installation Instructions
Device-Specific Safety Regulations ................................................................................................................... 2
Check List .......................................................................................................................................................... 3
Technical Data ................................................................................................................................................... 4
Device Construction ........................................................................................................................................... 6
Installation Notes for Split Air Conditioners ....................................................................................................... 7
Minimum Clearances .................................................................................................................................... 9
Assembling the Outdoor Unit ........................................................................................................................... 10
Connecting the Cooling System....................................................................................................................... 11
Pre-filled Refrigerant Pipes .............................................................................................................................. 12
Installation Notes – Laying a Split Pipe ........................................................................................................... 15
Electrical Connection ....................................................................................................................................... 17
Start-Up – Function Test .................................................................................................................................. 18
Refrigeration Plan ............................................................................................................................................ 19
Circuit Diagrams............................................................................................................................................... 20
Operating Instructions
Important Notes on Operation.......................................................................................................................... 23
Direction of Air Flow.................................................................................................................................... 24
Cleaning and Maintenance ......................................................................................................................... 24
Remote Control ................................................................................................................................................ 25
Battery for Remote Control ......................................................................................................................... 25
Functions of Remote Controls KSS 2504 / 3204 / 4504 / 6004.................................................................. 26
Cooling ........................................................................................................................................................ 27
Heating........................................................................................................................................................ 28
Dehumidification ......................................................................................................................................... 29
Auto............................................................................................................................................................. 30
Timer Function ............................................................................................................................................ 31
Sleep Function ............................................................................................................................................ 32
Faults .......................................................................................................................................................... 33
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1

KSS 2504 KSS 3204 KSS 4504 KSS 6004 Split Air Conditioner for Wall Mounting Installation and Operating Instructions 453322.66.11 06/07/B

Seite 2 - General Safety Requirements

10Assembling the Outdoor Unit The outdoor unit should be attached firmly to a suitable surface or a suitable wall of sufficient strength (see also “

Seite 3 - Check List

11Connecting the Cooling System First, unwind the refrigerant pipes carefully to their full length. The pipes may not have more than 3 bends in succ

Seite 4 - Technical Data

12Pre-filled Refrigerant Pipes Order identification KMSL 1438A-2 KMSL1438A-5 KMSL 3858-2 KMSL 3858-5 KMSL 1412A-2 KMSL1412A-5 Scope of

Seite 5

13Caution! The connections of the room air conditioner are equipped with various self-sealing single couplings. (The connection valve on the outdoor

Seite 6 - Device Construction

14Step 5: Now use a spanner to firmly connect the two halves of the coupling (essential to ensure the refrigerant circuit does not leak). Screw locks

Seite 7

15 Installation Notes – Laying a Split Pipe Siphon-shaped bending of the split pipes Caution!

Seite 8 - Wall opening:

16Step 7: When the cooling system connection has been completed*, open the valves (#) for the suction and liquid pipes at the outdoor unit. (Remove c

Seite 9 - Minimum Clearances

17Electrical Connection The room air conditioners are designed for operation with 230 V AC. The electrical safety of the device is ensured only if i

Seite 10 - Assembling the Outdoor Unit

18Start-Up – Function Test Start-Up Before switching on the power supply or making a test run, check whether: 1. All electrical connections are p

Seite 11 - Connecting the Cooling

19Refrigeration Plan Capillaries Collector Damper Compressor Evaporator Coupling 4-way valve Condenser Filter drier Filter drier Coupling

Seite 12 - KMSL 1412A-2 KMSL1412A-5

2General Safety Requirements  Please read these installation and operating instructions carefully and fully before commencing installation! They co

Seite 13 - Caution!

20Circuit Diagrams Stromlaufplan KSS 3204 Circuit diagram KSS 2504

Seite 14

21 Circuit diagram KSS 3204

Seite 15 - Minimum height

22 Circuit diagram KSS 4504 – outdoor unit Circuit diagram KSS 6004 – outdoor unit

Seite 16 - (length of split pipe)

23Important Notes on Operation The room air conditioner may not be used for any purpose other than room cooling, heating or dehumidification or air

Seite 17 - Electrical Connection

24Direction of Air Flow Up – down air flow The direction of the air flow of the air conditioner switches constantly from up to down (swing operation

Seite 18 - Start-Up – Function Test

Remote Control Battery for Remote Control Remove the cover of the battery compartment. Insert two 1.5 V batteries (type AAA), making sure that the

Seite 19 - Refrigeration Plan

26Functions of Remote Controls KSS 2504 / 3204 / 4504 / 6004 Remote control function keys 1. SWING key Sets the desired air outflow direction, automa

Seite 20 - Circuit Diagrams

27Cooling If the room temperature is higher than the temperature setting in the display, cooling is activated; if the room temperature is lower than

Seite 21 - Circuit diagram KSS 3204

28Heating If the room temperature is lower than the temperature set in the display, heating is activated. If the room temperature is higher than the

Seite 22

29Dehumidification If the room temperature falls to more than 2 °C below the value set, the fan in the indoor and outdoor compartments stops. At roo

Seite 23 - Important Notes on Operation

3Check List  Has a calculation of the cooling load been made?  Is the cooling capacity of the device sufficient for the room to be cooled?  Are

Seite 24 - Cleaning and Maintenance

30Auto In Auto mode, the air conditioner operates with pre-set, fixed temperatures for the cooling and heating modes. At room temperatures over 25 °

Seite 25 - Remote Control

31Timer Function Timer On: This function should*1 be programmed only when the device is non-operational. Pressing the key once sets a period of 30

Seite 26 - Remote control displays

32Sleep Function Depending on the operating mode, pressing the SLEEP key changes the temperature set by 1 °C every hour for a maximum of two hours

Seite 27 - Cooling

33Faults If a fault occurs (e.g. inadequate performance, smoke formation, unusual smell, loud noise, frequent cut-outs, electrical connections overh

Seite 28 - Heating

34Energy Efficiency Energy Room air conditioner Manufacturer: Dimplex Dimplex Dimplex Dimplex Outdoor unit KSS 2504A A KSS 3204A A KSS 4504C A K

Seite 29 - Dehumidification

35Warranty Authorised dealers can provide information on the terms and conditions of warranty. The warranty is not valid without a sales receipt mark

Seite 30

36 Glen Dimplex Deutschland GmbH Phone: +49 (0) 9221 709 562 Subject to technical modifications Am Goldenen Feld 18 Fax: +49 (0) 9221 709 565

Seite 31 - Timer Function

4Technical Data Split room air conditioners with rapid refrigerant coupling Indoor unit Outdoor unit KSS 2504 AB KSS 2504 A KSS 2504AI KSS 250

Seite 32 - Sleep Function

5 Split room air conditioners with rapid refrigerant coupling Indoor unit Outdoor unit KSS 4504 CB KSS 4504 C KSS 4504CI KSS 4504CA KSS 6004

Seite 33

6 Device Construction Outdoor component Room component (1) Casing flap (2) Air filter (3) Air filter Element A (option only) (4) Air filter Elem

Seite 34 - Room air conditioner

7Installation Notes for Split Air Conditioners Before choosing a room air conditioner, we recommend carrying out a cooling load calculation accordin

Seite 35 - Disposal notice

8Assembling the Indoor Unit Mounting plate: The mounting plate for the indoor unit must be positioned horizontally and attached firmly. Minimum clea

Seite 36

9Minimum Clearances Indoor unit The following minimum clearances (A and B) from walls are essential for the trouble-free operation of the room air

Kommentare zu diesen Handbüchern

Keine Kommentare