Fireplace Installation
Built-In Instructions
WARNING: The installation of
the replace unit must comply
with the applicable local and/or
national electrical codes and
utility requirements. This
installation should be
entrusted to duly qualied
personnel where required by
law.
Leave the frame uninstalled
from the replace chassis until
step 13.
Prepare a wall opening
following the dimensions shown in
Figure 4. Note that a 102 mm
minimum depth including the
thickness of dry wall is required.
Make sure there is enough
clearance for the cable coming
out from the bottom of the
replace.
!
NOTE: Where there are close
tolerances involved in wall
building or applications which
require a great degree of
precision, we recommend that
the product itself be used to
make the actual
measurements for the wall
opening. Dimplex will not be
responsible for inaccuracies in
the design or manufacture of
enclosures.
WARNING: Ensure method of
installation does not obscure
the air intake slots on top of
unit in any manner.
Keep a minimum of a 102 mm
clearance from top of unit to
any surface or material.
Wire a dedicated, properly
fused circuit with 240 Volt, 10
Amp rating. Allow up to 2.44 m
of service cable for connecting
power supply to junction box on
replace when installing after
nishing wall.
CAUTION: Use a two (2)
conductor, non-metallic sheath
cable with ground wire (three
(3) wires total) for the incoming
power supply on replace
inserts.
Figure 4
813
mm
362 mm