Dimplex QM125 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Raumheizungen Dimplex QM125 herunter. Dimplex QM125 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
- 1 -
Installation Instructions
IMPORTANT
These instructions should be read carefully and retained for
future use.
Note also the information presented on the appliance.
Quantum Heater
Models: QM070 QM100 QM125 QM150
Boost
Output
230/240V~:
567/630W 792/880W 1017/1130W 1242/1380W
Storage
Element
Rating
230/240V~: 1435/1560W 2042/2220W 2540/2760W 3024/3300W
Rated
Charge
Period: 7.7 - 7 Hours
Energy Cells: 18 24 30 36
Installed
Weight: 91kg 115kg 142kg 165kg
kWh: 10.9kWh 15.4kWh 19.3kWh 23.1kWh
A world of expertise
11115-4
Rev. 81/91
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Installation Instructions

- 1 -Installation InstructionsIMPORTANT These instructions should be read carefully and retained for future use. Note also the information presented o

Seite 2 - IMPORTANT

- 10 -Building the Heater Core10. Remove the inner front to gain access to the core of the heater. Lay the inner front carefully to one side to ensur

Seite 3 - 300mm of the front of the

- 11 -BricksThe bricks are supplied separately to the heater in packs of three.The reference number is 047243.12. The bricks have several grooves on

Seite 4 - X’, see Fig. 2

- 12 -14. The third row of brick is positioned in a manner similar to the fi rst row. Again be careful not to damage or dislodge the element.15. Fit

Seite 5

- 13 -Fig. 1717. Close the core by refi tting the inner front panel complete with insulation. Ensure the bottom edge is located inside the chassis an

Seite 6 - Installing the Heater

- 14 -IMPORTANTDuring the initial operation some odour may be noticed due to the newness of materials used in manufacture. This is normal and will dis

Seite 7

- 15 -Auto BoostThe boost element can be enabled to automatically be energised during the comfort period by selecting ‘Auto Boost’. Factory Setting A

Seite 8 - Electrical Connections

- 16 -Circuit DiagramINDICATES ORANGE WIREINDICATES WHITE WIREFILTERFANACNNLACLFAN RESISTORROOMTHERMISTORPCBUSERINTERFACEBLACKROOMREDFANWHITECOREELEME

Seite 9 - CENELEC - H05V2V2-F

- 2 -IMPORTANT WARNING - THE SURFACE OF THIS HEATER CAN BE HOT.WARNING - THIS APPLIANCE MUST BE EARTHED.• The installation must be carried out by a s

Seite 10 - Building the Heater Core

- 3 - Where particularly vulnerable people are likely to be left unsupervised in the vicinity of the heater we recommend that a guard is fi tted aroun

Seite 11

- 4 -Preparation 1. Place the heater fl at on the ground with arrows printed on the base of the carton pointing upwards.Open the carton at the bottom,

Seite 12

- 5 -3. Ensure the heater is stable before removing the screws which hold the grille panel in position. Set the grille to one side.4. Remove the tw

Seite 13 - Reassembly

- 6 -Installing the Heater The heater must be securely fi xed to a wall. Screws with suitable wall fi xings for solid walls are provided. If other wal

Seite 14

- 7 -Fig. 6Fig. 76. Place the heater in its fi nal position and mark the fi xing holes through the location holes visible through the back of the heate

Seite 15 - Information

- 8 -Electrical Connections8. The heater leaves the factory confi gured to operate with two mains supplies, a 24 hour supply and an off peak switched

Seite 16 - Circuit Diagram

- 9 -9. The mains cable entry bushes and terminal blocks will be visible on the right hand side of the unit. Insert the mains cables through the cab

Kommentare zu diesen Handbüchern

Keine Kommentare