Fireplace Installation
!
NOTE: A 10 Amp, 240 Volt
circuit is required. A dedicated
circuit is preferred but not
essential in all cases. A
dedicated circuit will be
required if, after installation,
the circuit breaker trips or the
fuse blows on a regular basis
when the heater is operating.
Additional appliances on the
same circuit may exceed the
current rating of the circuit
breaker.
CAUTION: The heater must
not be located immediately
above or below a socket
outlet.
WARNING: Ensure the power
cord is not installed so that it is
pinched or against a sharp
edge and ensure that the
power cord is stored or
secured to avoid tripping or
snagging to reduce the risk of
! re, electric shock or injury to
persons.
Construction and electrical
outlet wiring must comply with
local building codes and other
applicable regulations to
reduce the risk of ! re, electric
shock and injury to persons.
Do not attempt to wire your
own new outlets or circuits. To
Quick Reference Guide
Before using the In-Stud
! replace verify:
Are the circuit breakers for the
unit on?
Are the light bulbs loose? (To
check, follow the instructions
for replacing the light bulbs
under the maintenance section
of this manual)
The heater may emit a slight,
harmless odor when ! rst used.
This odor is a normal condition
caused by the initial heating of
internal heater parts.
The information regarding the
model of your unit can be found
on the model and serial number
plate located on the side of the
unit. See Page 3 for an illustration
on how to locate the rating plate.
reduce the risk of ! re, electric
shock or injury to persons,
always use a licensed
electrician.
WARNING: The Convex In-
Stud ! replace is wall
mountable and can be built in
a wall space 406 mm over-
center between 2 x 4 wall
studs. Follow the installation
instructions for either wall
mount or built-in mounting;
failure to do so may
cause damage or injury.
Wall Mounting Instructions
Leave the glass assembly
uninstalled until step 10.
Select a location for the
! replace, preferably above an
electrical outlet and there must
be at least one wall stud behind
for the ! replace to mount onto.
The bottom of the unit must be
a minimum of 356 mm above
the " oor (mounting holes 0.75 m
minimum above the " oor)
(Figure 1).
Access to the electrical outlet
must be maintained. Ensure the
installation meets the national and
state/provincial electrical codes.
Fireplace Installation
!
NOTE: It is recommended
that the bottom of the unit not
be
mounted higher than
1.22 m from the ground to
maintain an optimized viewing
angle of the " ame.
CAUTION: The ! replace
must be mounted at two (2)
points, one of which must be
on a wall stud.
WARNING: High
temperatures may be
Figure 1