Dimplex Heatbook
Technical information
UNDER-TILE WARMING
Mat construction
• Twin core 160W/m
2
cable
• Fully screened for use in
bathrooms or other wet areas
• Two layers of insulation for
maximum cable life
• Easy to cut mesh backing that
can be removed for small and
awkward areas
Installation
The Dimplex under-tile heating mats
can be fitted to:
• Timber suspended floors
• Concrete solid floors
• Dimplex strongly recommends
the use of 10mm insulating
tile backer board to maximise
system performance
Electrical
• All installations should be carried
out by a qualified electrician in
accordance with the current
wiring regulations
• All installations require an
RCD (residual current device)
for safe operation
• The Dimplex thermostatic controller
has a maximum load of 15A
• Connecting more than two mats
to a controller requires the use of
a standard electrical junction box
• The Dimplex thermostatic
controller comes complete
with a floor sensing probe
A
B
Model
Electrical
rating Accuracy Width Height Depth Total depth
DTW16S 15A 0.5°C 79mm 83mm 22mm 44mm
Always use a standard electrical junction box when connecting more than two mats.
Model Output at 230V Area Element depth Width A Length B
DTW1M 160W 1.0m
2
3mm 500mm 2000mm
DTW1.5M 240W 1.5m
2
3mm 500mm 3000mm
DTW2M 320W 2.0m
2
3mm 500mm 4000mm
DTW3M 480W 3.0m
2
3mm 500mm 6000mm
DTW4M 640W 4.0m
2
3mm 500mm 8000mm
DTW5M 800W 5.0m
2
3mm 500mm 10000mm
DTW6M 960W 6.0m
2
3mm 500mm 12000mm
Each mat comes with adhesive roll and instruction for installation.
Dimensions
Mat dimensions and loadings
Sizing guide
Controller dimensions and loadings
Floor length
1m 1.5m 2m 3m 4m 5m
Floor width
1m
1 x DTW1M 1 x DTW1.5M 1 x DTW2M 1 x DTW3M 1 x DTW4M 1 x DTW5M
1.5m
1 x DTW1.5M 1 x DTW2M 1 x DTW3M 1 x DTW4M 1 x DTW6M
1 x DTW6M +
1 x DTW1.5M
2m
1 x DTW2M 1 x DTW3M 1 x DTW4M 1 x DTW6M 2 x DTW4M 2 x DTW5M
3m
1 x DTW3M 1 x DTW4M 1 x DTW6M 3 x DTW3M 2 x DTW6M 3 x DTW5M
4m
1 x DTW4M 1 x DTW6M 2 x DTW4M 2 x DTW6M 4 x DTW4M 4 x DTW5M
5m
1 x DTW5M
1 x DTW6M +
1 x DTW1.5M
2 x DTW5M 3 x DTW5M 4 x DTW5M 5 x DTW5M
Note: Always choose heater packs that are slightly smaller than your requirement as only the mesh
can be cut (Not the wire!) This chart is for illustrative purposes only.
Do not place under-tile heating under permanent fixtures (e.g. baths, kitchen cupboards).